Welcome to Beijing Bangxuan Mosaic!

13716334909

Call us anytime

13716334909

Send Email

2199206852@qq.com

Walk-in temperature humidity test chamber

Walk-in temperature humidity test chamber

Introduction of walk-in temperature humidity test chamberThe walk-in constant temperature humidity test chamber is a large temperature and humidity te

Free Quote

Introduction of walk-in temperature humidity test chamber

The walk-in constant temperature humidity test chamber is a large temperature and humidity test chamber. Its temperature and humidity range is almost the same as the small temperature humidity chamber. Due to the large internal volume, the power of the walk-in test room is higher than that of the small test box under the same temperature and humidity conditions.

The functions of the small constant temperature and humidity test chamber are the same with the walk-in type. Except that it cannot be moved at will and does not include the castor wheel, other configurations are similar.

The walk-in test chamber is used to test the response of products and materials to high and low-temperature humidity, or constant temperature and humidity environmental changes, and the parameters and corresponding properties are obtained.

The smallest walk-in chamber has 6-8 cubic meters and can be designed according to the customer's room layout.

All parts used in Noki's walk-in temperature humidity test chambers are brand new, and we never use second-hand or repaired parts.

The main functional components are all international brands, the technical principle is advanced and reliable, and the noise and energy saving are optimally controlled.

All wires in the control cabinet have serial numbers and numbers printed by special equipment, and the lines are clean and clear at a glance.

Due to the large environmental impact, Noki currently recommends customers make the walk-in outer dimension into the inner dimension of a container, which is convenient for transportation. Of course, if you really don't want to modify the size, it must be made into a size of 4*3*3m, and we have no problem. Just the shipping cost would be high because the normal container can not load such a huge machine.

At present, the largest walk-in model made by Noki is 600 cubic meters.

Walk-in constant temperature humidity test chamber form

(1) Sheet metal type

Sheet metal type is also called library plate type. During installation, the master worker assembles the pieces of the library board together by welding. This method is troublesome to assemble and requires the patience of the worker master to weld the library boards together like building blocks. The advantage is that this way of assembly is easy to transport. Just stack the library boards like furniture and pack them one by one.

This assembly method requires that the master worker has considerable proficiency in welding and is very familiar with the components of the equipment. Higher requirements for workers and masters.

(2) All in one

One-piece, as the name suggests, means that the entire walk-in temperature humidity test chamber is formed in one piece. No need to assemble the library board.

The disadvantage is that it occupies a large area, is inconvenient to transport, and has a high cost.

The advantage is that because it is integrally formed, the sealing is very good, and the heat preservation and moisturizing effect are better. If the customer conducts the high-temperature section test, the equipment will not be cracked due to the presence of welds.

Walk-in temperature humidity test chamber working principle

The walk-in temperature humidity test chamber is equipped with forced heating, forced cooling, forced humidification, and forced dehumidification through the air to the working space. The test chamber has an air room, a circulating air duct heating device, a cooling device, a humidifying device, and a circulating fan. Diffuser;

The temperature and humidity controller sends instructions according to the set temperature and humidity, and the temperature and humidity sensor in the test room transmits signals and controls the output of the heating and humidifier through the PID intelligent adjustment and SSR control module, the refrigeration unit works, and the circulating air is evenly distributed.

The top is blown out, and it is recovered from the bottom after passing through the test space to form a closed-loop control mode, so as to achieve the purpose of long-term stable operation.

Walk-in temperature humidity test chamber basic parameters

Test room sizeAccording to the customer room floor plan
Temperature range-70~100℃
Humidity range20-95%RH
Temperature and humidity uniformity±2℃, ±5%RH
Heating time-40~150℃≤45 min
Cooling time+20~-70℃ ≤120 min
Use environment5~30℃, ≤85%RH
VoltageAC380V 50Hz, three-phase 5 wires system
DoorSingle/double door, left/right opening (size can be customized)
Sample holderThe size depends on the size of the test room
Test holeStandard 50mm diameter

Optional choices

Fingerprint door lockOperator controllable
SMS alarmThrough SMS alarm, keep abreast of equipment conditions
PrinterMicro printer, ready to print test data
UV lightUV spectral range: 320~400nm
GlareCool white fluorescent 0~6000LX adjustable±500LX

The applicable standard for walk-in temperature humidity test chamber

1. GB2423.1-2008/IEC6008-2-1-2007 Environmental Testing of Electrical and Electronic Products Part 2: Test Method A: Low Temperature;

2. GB/T 2423.2-2008 Environmental Testing of Electrical and Electronic Products Part 2: Test Method Test B: High Temperature;

3. GJB150.3A-2009 High-temperature test method;

4. GJB150.4A-2009 Low-temperature test method;

5. GB2423.22-2008 Environmental Testing of Electrical and Electronic Products Part 2 Test Method Test Nb: Temperature change with specified temperature change rate;

6. GBT 2424.5-2006 Environmental test chamber performance confirmation for electrical and electronic products;

7. GB/T 10589-2008 Technical conditions of low-temperature test chamber;

8. GB/T2423.3-2008 (IEC68-2-3) Test Ca: constant damp heat test method;

9. GJB150.9A-2009 Damp heat test method;

10. G/BT 2423.4-2008/IEC6008-2-30:2005 Test Db: Alternating Damp Heat Method;

11. GB/T5170.18-2005 Basic parameter verification method of environmental test equipment for electrical and electronic products Temperature/humidity combined cycle test equipment;

12. GB/T10586-2006 Technical conditions of damp heat test chamber;

13. GBT 2424.6-2006 Performance Confirmation of Temperature and Humidity Test Chamber for Environmental Testing of Electrical and Electronic Products;

14. GBT 2424.7-2006 Environmental test for electrical and electronic products A and B (with load) temperature test chamber measurement

Walk-in test chamber structures

The interior of the walk-in test chamber is made of 304 stainless steel 1.0mm, and the outer box is made of sprayed cold-rolled plate 1.5mm. A visual window can be added to the door of the test room, which is convenient for operators to observe the interior of the test room.

In order to prevent the chamber body from being deformed, 80# channel steel is used inside the chamber body to strengthen it to prevent the chamber door from being deformed due to excessive weight and affecting the sealing performance.

The insulation material of the housing body is made of polyurethane ultra-fine glass fiber cotton, and the thickness can be customized. The thickness of the current product range is 100-200mm. The thicker the thickness, the higher the price.

Due to the large walk-in, LED illumination is generally standard. Standard 50mm diameter test hole with silicone plug. If the customer has demand, the number of test holes can be increased, which is convenient for testing a large number of samples. Advance notice is required.

The walk-in test chamber is equipped with a touch screen control panel as standard, with a sound and light alarm system and protection system. Pure English operation interface: users can control temperature and humidity, test cycle items, etc, by simply tapping the panel, which is very convenient. The USB export port is under the control panel, which is convenient for customers to export test data results at any time.

The test room can be made into a single door or double door according to customer requirements, depending on customer needs, there is no additional cost.

The water tank is located near the unit cabinet of the whole walk-in test chamber and has water shortage protection. There is a Φ10mm external water inlet in the lower part of the chamber after the inspection. The purpose of the laboratory is unguarded. The test water can be switched between an automatic recovery cycle and no recovery.

Walk-in test chamber production process

(1) Sheet metal

Open-Bend-Welding-Polishing-Spray

(2) Assembly

Structural assembly: parts assembly, complete machine assembly

Electrical assembly

Refrigeration assembly

Plumbing assembly

(3) Debug

Electrical debugging

Refrigeration test

Water test

Control test

Stability test

Parametric test

(4) Inspection

Visual inspection

Electrical operation inspection

Refrigeration inspection

Structural position inspection

Label inspection

Packaging Inspection

Transport inspection

Applicable conditions of walk-in temperature humidity test chamber

Cooling methodAir cool
VoltageAC 380V±10%、50 Hz、3 phase 5 wires system
Due to the large power used by the equipment, the user needs to prepare a five-core (three-phase four-wire + protective ground wire) cable from the equipment to the power distribution cabinet.
Ambient temperature0~35℃
Environment humidity< 85%R.H
Atmospheric pressure86~106Kpa。
Site requirementsThe equipment should be placed horizontally in a well-ventilated test room, and there should be enough space around for operation and maintenance; it is best to have floor drains near the test box.
Environmental conditionsThere is no strong vibration, no strong electromagnetic field interference, no high-concentration dust and corrosive substances, no direct sunlight or direct radiation from other heat sources around the equipment site.
Walk-in temperature humidity test chamber docs provided

(1) Certificate of Conformity

(2) Instruction Manual

(3) Electrical schematic diagram

(4) Schematic diagram of a low-temperature system

(5) Instrument Instruction Manual

(6) Warranty Card

(7) Packing list

Walk-in test chamber voltages

AC220V 50HZ Single-phase three-wire system, single-phase 220V

Can adapt 110V, 230V, 240V, 360V, 380V, 415V, etc

Leave a Message